Good quality Stewart And Gee Tangent Galvanometer - 3D Scanner-CO2-C70 – FEELTEK
Good quality Stewart And Gee Tangent Galvanometer - 3D Scanner-CO2-C70 – FEELTEK Detail:
Product characteristics
Description
- Standard XY2-100 protocol,open interface, compatible with popular control card on the market.
- Support wavelength: 10640nm10200nm9400nm.
- Design of positive pressure cavity to effectively ensure the cleanliness of optical path system.
- Real-time feedback digital drive technology to achieve higher positioning accuracy and machining characteristics.
- The controllable of Z axis optical design, easy to achieve working field switch and its corresponding focal point set70mm aperture size, easy to achieve 2000mm×2000mm working field.
- Ultra-fine spot, minimum spot diameter 0.12mm@350×350@10640.
Application
Roll to roll leather marking,Carving,Precision film cutting,Drilling
Version
Pro,P2
General specification
Power Supply |
InputVoltage(VAC) |
170~264 |
OutputVoltage(VDC) |
±24/±28 |
|
Current(A) |
4A(3sets) |
1)Three power supply independently
Cooling condition
Coolina media |
Distilled or de-ionized water plus corrosion inhibitor |
Temperature |
22-28℃ |
Suggestcoolingpressure |
2-3bar |
Recommendedflowrate |
4-6(l/min) |
Purge gas
Purge gas |
N2 (purity 99.95%) or Clean, Dry Air(purity 99.995%,oil free, 1 micron filtered) |
Dewpoint temperature |
10degreeslowerthaninletcoolantwaterto the sub-system |
Recommendedflowrate |
2.8~3.5 l/min |
*Other gas which not meet the specification stated above is not permitted to apply to this sub-system.
Environmental requirement
Ambienttemperature(°) |
25±10 |
Storagetemperature(°) |
-10~+60 |
Humidity |
≤75% non condensing |
Galvanometer Specifications
Scan Angle(°) |
±11 |
Repeatability(μrad) |
8 |
Max. Gain Drift(ppm/K) |
100 |
Max. Offset Drift(μrad/K) |
30 |
Long-termdriftover8h(mrad) |
0.5 |
Max.processingspeed(mm/s) |
8000mm/s@1200x12004000mm/s@650×650 |
Tracking Error(ms) |
≤1.2 |
Optical specifications
Reflect mirror |
SIC |
Wavelength |
10600nm |
Single lens transmission |
≥99.7% |
System transmission |
≥82% |
Aperture Size |
≤65mm |
Subsysteminputbeamdiameter |
9mm/13mm/20mm |
Coating index |
1/2入(PV) |
*pw is not include in standard configuration
Working filed & Spot Diamete
Working Field(mm) |
Large Field Version |
700×700 |
800×800 |
900×900 |
1000×1000 |
Focal length(mm) |
761 |
881 |
1001 |
1121 |
|
The Min. Spot Diameter@1/e2(mm) |
0.27 |
0.31 |
0.34 |
0.38 |
Working Field(mm) |
Large Field Version |
1200×1200 |
1600×1600 |
200×2000 |
Focal length(mm) |
1361 |
1841 |
2321 |
|
The Min. Spot Diameter@1/e2(mm) |
0.43 |
0.54 |
0.64 |
Working Field(mm) |
Small FieldVersion |
350×350 |
450×450 |
550×550 |
Focal length(mm) |
341 |
461 |
581 |
|
TheMin.SpotDiameter @1/e2(mm) |
0.134 |
0.162 |
0.188 |
Working Field(mm) |
Small FieldVersion |
650×650 |
750×750 |
850×850 |
Focal length(mm) |
701 |
821 |
941 |
|
TheMin.SpotDiameter @1/e2(mm) |
0.221 |
0.251 |
0.282 |
Product detail pictures:
Related Product Guide:
We stay with the basic principle of "quality initially, services first, steady improvement and innovation to fulfill the customers" for your management and "zero defect, zero complaints" as the quality objective. To perfect our company, we give the goods while using the good high-quality at the reasonable selling price for Good quality Stewart And Gee Tangent Galvanometer - 3D Scanner-CO2-C70 – FEELTEK , The product will supply to all over the world, such as: belarus , Estonia , Pakistan , Our company always concentrate on the development of the international market. We have a lot of customers in Russia , European countries, the USA, the Middle East countries and Africa countries. We always follow that quality is foundation while service is guarantee to meet all customers.
By Jean from Mexico - 2017.03.07 13:42
The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!
By Martin Tesch from Mauritius - 2017.02.14 13:19