Good quality Stewart And Gee Tangent Galvanometer - 3D Scanner-CO2-C70 – FEELTEK
Good quality Stewart And Gee Tangent Galvanometer - 3D Scanner-CO2-C70 – FEELTEK Detail:
Product characteristics
Description
- Standard XY2-100 protocol,open interface, compatible with popular control card on the market.
- Support wavelength: 10640nm10200nm9400nm.
- Design of positive pressure cavity to effectively ensure the cleanliness of optical path system.
- Real-time feedback digital drive technology to achieve higher positioning accuracy and machining characteristics.
- The controllable of Z axis optical design, easy to achieve working field switch and its corresponding focal point set70mm aperture size, easy to achieve 2000mm×2000mm working field.
- Ultra-fine spot, minimum spot diameter 0.12mm@350×350@10640.
Application
Roll to roll leather marking,Carving,Precision film cutting,Drilling
Version
Pro,P2
General specification
Power Supply |
InputVoltage(VAC) |
170~264 |
OutputVoltage(VDC) |
±24/±28 |
|
Current(A) |
4A(3sets) |
1)Three power supply independently
Cooling condition
Coolina media |
Distilled or de-ionized water plus corrosion inhibitor |
Temperature |
22-28℃ |
Suggestcoolingpressure |
2-3bar |
Recommendedflowrate |
4-6(l/min) |
Purge gas
Purge gas |
N2 (purity 99.95%) or Clean, Dry Air(purity 99.995%,oil free, 1 micron filtered) |
Dewpoint temperature |
10degreeslowerthaninletcoolantwaterto the sub-system |
Recommendedflowrate |
2.8~3.5 l/min |
*Other gas which not meet the specification stated above is not permitted to apply to this sub-system.
Environmental requirement
Ambienttemperature(°) |
25±10 |
Storagetemperature(°) |
-10~+60 |
Humidity |
≤75% non condensing |
Galvanometer Specifications
Scan Angle(°) |
±11 |
Repeatability(μrad) |
8 |
Max. Gain Drift(ppm/K) |
100 |
Max. Offset Drift(μrad/K) |
30 |
Long-termdriftover8h(mrad) |
0.5 |
Max.processingspeed(mm/s) |
8000mm/s@1200x12004000mm/s@650×650 |
Tracking Error(ms) |
≤1.2 |
Optical specifications
Reflect mirror |
SIC |
Wavelength |
10600nm |
Single lens transmission |
≥99.7% |
System transmission |
≥82% |
Aperture Size |
≤65mm |
Subsysteminputbeamdiameter |
9mm/13mm/20mm |
Coating index |
1/2入(PV) |
*pw is not include in standard configuration
Working filed & Spot Diamete
Working Field(mm) |
Large Field Version |
700×700 |
800×800 |
900×900 |
1000×1000 |
Focal length(mm) |
761 |
881 |
1001 |
1121 |
|
The Min. Spot Diameter@1/e2(mm) |
0.27 |
0.31 |
0.34 |
0.38 |
Working Field(mm) |
Large Field Version |
1200×1200 |
1600×1600 |
200×2000 |
Focal length(mm) |
1361 |
1841 |
2321 |
|
The Min. Spot Diameter@1/e2(mm) |
0.43 |
0.54 |
0.64 |
Working Field(mm) |
Small FieldVersion |
350×350 |
450×450 |
550×550 |
Focal length(mm) |
341 |
461 |
581 |
|
TheMin.SpotDiameter @1/e2(mm) |
0.134 |
0.162 |
0.188 |
Working Field(mm) |
Small FieldVersion |
650×650 |
750×750 |
850×850 |
Focal length(mm) |
701 |
821 |
941 |
|
TheMin.SpotDiameter @1/e2(mm) |
0.221 |
0.251 |
0.282 |
Product detail pictures:
Related Product Guide:
Our items are commonly identified and trusted by people and can fulfill repeatedly altering economic and social wants of Good quality Stewart And Gee Tangent Galvanometer - 3D Scanner-CO2-C70 – FEELTEK , The product will supply to all over the world, such as: Auckland , Angola , United Kingdom , We follow up the career and aspiration of our elder generation, and we are eager to open up a new prospect in this field, We insist on "Integrity, Profession, Win-win Cooperation", because we have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
By Belinda from Macedonia - 2017.10.27 12:12
Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
By Michelle from Southampton - 2017.09.22 11:32