OEM Factory for Range Of Galvanometer - 3D Scanner-CO2-C70 – FEELTEK
OEM Factory for Range Of Galvanometer - 3D Scanner-CO2-C70 – FEELTEK Detail:
Product characteristics
Description
- Standard XY2-100 protocol,open interface, compatible with popular control card on the market.
- Support wavelength: 10640nm10200nm9400nm.
- Design of positive pressure cavity to effectively ensure the cleanliness of optical path system.
- Real-time feedback digital drive technology to achieve higher positioning accuracy and machining characteristics.
- The controllable of Z axis optical design, easy to achieve working field switch and its corresponding focal point set70mm aperture size, easy to achieve 2000mm×2000mm working field.
- Ultra-fine spot, minimum spot diameter 0.12mm@350×350@10640.
Application
Roll to roll leather marking,Carving,Precision film cutting,Drilling
Version
Pro,P2
General specification
Power Supply |
InputVoltage(VAC) |
170~264 |
OutputVoltage(VDC) |
±24/±28 |
|
Current(A) |
4A(3sets) |
1)Three power supply independently
Cooling condition
Coolina media |
Distilled or de-ionized water plus corrosion inhibitor |
Temperature |
22-28℃ |
Suggestcoolingpressure |
2-3bar |
Recommendedflowrate |
4-6(l/min) |
Purge gas
Purge gas |
N2 (purity 99.95%) or Clean, Dry Air(purity 99.995%,oil free, 1 micron filtered) |
Dewpoint temperature |
10degreeslowerthaninletcoolantwaterto the sub-system |
Recommendedflowrate |
2.8~3.5 l/min |
*Other gas which not meet the specification stated above is not permitted to apply to this sub-system.
Environmental requirement
Ambienttemperature(°) |
25±10 |
Storagetemperature(°) |
-10~+60 |
Humidity |
≤75% non condensing |
Galvanometer Specifications
Scan Angle(°) |
±11 |
Repeatability(μrad) |
8 |
Max. Gain Drift(ppm/K) |
100 |
Max. Offset Drift(μrad/K) |
30 |
Long-termdriftover8h(mrad) |
0.5 |
Max.processingspeed(mm/s) |
8000mm/s@1200x12004000mm/s@650×650 |
Tracking Error(ms) |
≤1.2 |
Optical specifications
Reflect mirror |
SIC |
Wavelength |
10600nm |
Single lens transmission |
≥99.7% |
System transmission |
≥82% |
Aperture Size |
≤65mm |
Subsysteminputbeamdiameter |
9mm/13mm/20mm |
Coating index |
1/2入(PV) |
*pw is not include in standard configuration
Working filed & Spot Diamete
Working Field(mm) |
Large Field Version |
700×700 |
800×800 |
900×900 |
1000×1000 |
Focal length(mm) |
761 |
881 |
1001 |
1121 |
|
The Min. Spot Diameter@1/e2(mm) |
0.27 |
0.31 |
0.34 |
0.38 |
Working Field(mm) |
Large Field Version |
1200×1200 |
1600×1600 |
200×2000 |
Focal length(mm) |
1361 |
1841 |
2321 |
|
The Min. Spot Diameter@1/e2(mm) |
0.43 |
0.54 |
0.64 |
Working Field(mm) |
Small FieldVersion |
350×350 |
450×450 |
550×550 |
Focal length(mm) |
341 |
461 |
581 |
|
TheMin.SpotDiameter @1/e2(mm) |
0.134 |
0.162 |
0.188 |
Working Field(mm) |
Small FieldVersion |
650×650 |
750×750 |
850×850 |
Focal length(mm) |
701 |
821 |
941 |
|
TheMin.SpotDiameter @1/e2(mm) |
0.221 |
0.251 |
0.282 |
Product detail pictures:
Related Product Guide:
We goal to see good quality disfigurement within the manufacturing and provide the most effective support to domestic and overseas shoppers wholeheartedly for OEM Factory for Range Of Galvanometer - 3D Scanner-CO2-C70 – FEELTEK , The product will supply to all over the world, such as: Peru , Danish , Slovak Republic , Since always, we adhering to the "open and fair, share to get, the pursuit of excellence, and creation of value"values, adhere to the"integrity and efficient, trade-oriented, best way , best valve" business philosophy. Together with our all over the world have branches and partners to develop new business areas, maximum common values. We sincerely welcome and together we share in global resources, opening up new career together with the chapter.
By Queena from Jamaica - 2017.09.30 16:36
This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
By Elaine from Guinea - 2017.06.16 18:23