OEM Supply Galvanometer To Ammeter - PS Series-Advanced Option – FEELTEK
OEM Supply Galvanometer To Ammeter - PS Series-Advanced Option – FEELTEK Detail:
Application Video
Product Technical Information
Product line
Type | version | Weight(KG) | Size( mm) | Input voltage | Output Voltage(VDC) | Current(A) | Protocol |
PS10 PSH10 | Standard Version Pro.Version | 2.2 | 150x115x115 | 100V60HZ 220V50HZ | ±15 | 5 | XY2-100 Protocol |
PS15 PSH15 | Standard Version Pro.Version | 3.6 | 168x125x120 | ||||
PS20 PSH20 | Standard Version Pro.Version | 5.5 | 175x134x148.9 |
Optical Specifications
Type | Aperture size (mm) | Available Wavelength | Optical Material | Optical Surface |
PS10 PSH10 | 10 | 355 532 980/1064 9400 / 10640 | 1/4λ@633 Partly 1/8λ@633 | Si / Qu |
PS15 PSH15 | 15 | 355 532 980/1064 10640 | 1/4λ@633 | Si/SiC / Qu |
PS20 PSH20 | 20 | 355 532 980/1064 9400 / 10640 | 1/4λ@633 | Si/SiC / Qu |
Galvanometer Specifications
Type | PS10 (Standard Version ) | PSH10 (Standard Version ) | PS15 (Standard Version ) | PSH15 (Standard Version ) | PS20 (Standard Version ) | PSH20 (Standard Version ) |
Scan Angle(°) | ±11 | ±10 | ±10 | |||
Repeatability(urad) | 8 | 8 | 5 | 8 | 5 | |
Max.Gain Drift(ppm/k) | 100 | 50 | 50 | |||
Max.Offset Drift(urad/k) | 30 | 30 | 15 | |||
Long-term drift over 8h(mrad) | ≦0.15 | ≦0.1 | ≦0.1 | ≦0.1 | ||
Tracking Error(us) | <90 | <150 | <200 | |||
Step Response Time 1% of Full cale’(us) | <230 | <410 | <580 | |||
Typical Marking Speed²(m/s) | 7 | 5 | 4 | |||
Typical Positioning Speed²(m/s) | 20 | 15 | 14 | |||
Typical Character Marking³(cps) | 800CPS Good Quality 1000CPS Good Writing | 600CPS Good Quality 700CPS Good Writing | 650CPS Good Quality 750CPS Good Writing | 500CPS Good Quality 600CPS Good Writing |
1)1% step response 2)2D scanhead use F160 F-θ lens 3) F160 F-θ lens,1mm height single line character, LenMark software& FEELTEK control card
Mechanical Drawing
Product detail pictures:
Related Product Guide:
Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" plus the theory of "quality the basic, have faith in the main and management the advanced" for OEM Supply Galvanometer To Ammeter - PS Series-Advanced Option – FEELTEK , The product will supply to all over the world, such as: Comoros , Sheffield , Boston , Insisting over the high-quality generation line management and prospects guide provider, we've made our resolution to offer our shoppers using the initially stage purchasing and soon after provider working experience. Preserving the prevailing helpful relations with our prospects, we even now innovate our product lists the many time to meet up with the brand new wants and stick to the latest trend of this business in Ahmedabad. We're ready to facial area the difficulties and make the transform to grasp many of the possibilities in international trade.
By Gemma from Montpellier - 2017.12.09 14:01
The factory has advanced equipment, experienced staffs and good management level, so product quality had assurance, this cooperation is very relaxed and happy!
By Harriet from El Salvador - 2017.05.02 11:33
Write your message here and send it to us